Hayward pool heater lo - All AquaCal heaters represented within this manual are designed to operate successfully at flow rates of 30-to-70 gallons-per-minute (GPM). Design the plumbing system to maintain at least 50-GPM flow through the heater under worst case conditions (i.e.: filter fouled to 10 psi rise); the heat pump will not operate correctly, nor

 
Jan 5, 2024 · Exiting Bypass Operation. To exit bypass operation and resolve the bO Code problem, follow these steps: First, set the heater to standby mode. Next, press and hold the Down key and MODE key for three seconds. Finally, verify that the display no longer shows the “bO” indication. . Keswick theatre glenside pa seating chart

Remove front & rear panels Remove wires from limit switches. Step 13. Remove the 4 screws from the bottom of the front and rear panels and pull up and out to remove each one. Step 14. Use needle nose pliers to remove the 2 red wires from each of the high limit switches. Remove wires from water pressure switch.NJ. Aug 7, 2021. #1. Hello, I have a H150FDN pool heater. It's worked all summer so far, but last week I noticed that it would turn on for a few minutes then turn off and show Lo. The filter is clean and the output is strong. I ordered a new pressure switch, but in the meantime I took the two wires that connect to the switch and made a jumper ...May 25, 2022 · You need to put the heater in STANDBY Mode to get the bO code on the heater display. Press the mode button once to get the heater in STANDBY Mode. First, press and hold on to the Down key. Then, press and hold down the MODE key as well. You need to keep holding both keys for about three seconds. At this point, the “bO” message should appear ... The Hayward H-Series' Finn Plate cupro-nickel heat exchanger has special V-groove design for faster heating and longer life. Hayward Universal H-Series, Low NOx, 150,000 BTU, Natural Gas, Pool and Spa Heater delivers energy efficient heating to your pool's water that you can trust. Hayward Universal H-Series - Versatility & PowerLocate a dealer near you for all your needs: building or servicing your pool, buying a product, or warranty support.Hayward Pool Products Inc. is a leading manufacturer and distributor of swimming pool equipment and supplies. With over 80 years of experience, the company has been at the forefron...Most Pentair & Hayward heaters come standard as Low NOx. Low NOx is required for 5 counties in Southern California only, and for all commercial heaters in Texas only. ... Since some state laws mandate a Lo-Nox pool heater system, it’s important to be aware of your state health codes. For example, Lo-NOx is required for 5 counties in Southern ...Jul 17, 2021 ... Pools, Spas and Hot Tubs - Hayward pool heater troubleshooting help needed - I have a 4 year old H500FDPASME and it stopped working.Swimming Pool Heater Hayward H200FD Service & Installation Manual. Pool and spa/hot tub heaters (64 pages) Swimming Pool Heater Hayward H250FD Owner's Manual. ... 11. Service LED ON: “LO” Code Check continuity of Is water pressure Verify adequate water pressure “LO” Code switch wiring free of water flow, is switch, ...When your Hayward pool heater flashes the ‘bo code’, it’s signaling that there’s an issue with the bypass operation. Here’s a strategic approach to get your heater back to optimal functionality. Reset the Heater: Turn off the heater and the circuit breaker for 30 seconds. Power up the system again to see if the ‘bo code’ persists.Dive into a pool of knowledge with our Hayward Pools manuals and literature page, where you can search by SKU. Explore comprehensive guides, maintenance manuals, and essential literature for all your pool needs. Whether you're a beginner or a seasoned pool owner, find everything you need to keep your Hayward pool in perfect condition. Start …Reach out via phone at (908) 355-7995 or email for unparalleled customer service and technical support to keep your pool in optimal condition. ... Hayward Insights provides expert advice, ... Pump, Filter, Heater, Lights, & Whole Goods Tech Support. 1 (908) 355-7995 (U.S.) Contact us by letter: Hayward Holdings, Inc.LO Code Pages 40-43 IF Code Pages 44-46 AC Code Page 47 AO Code ... Heater must then be in Spa or Pool Mode for operation. The heater will ... Hayward Part # FDXLFSKF30 (Qty. 10) Step 1: Page 14 Verify incoming voltage to heater is present (110-125 or 220-245 VAC), if The Universal H-Series Low NOx heater has an 84 percent industry-leading thermal efficiency and complies with all current California air quality emission standards. The low NOx emission makes it a perfect choice for the environmentally concerned pool owner. Enjoy a warmer pool this season without your fuel costs skyrocketing. Heater must then be in Spa or Pool Mode for operation. The heater will fire when instructed by the external control. Control Configuration- Two wire Note: 104° maximum temperature. Step 1: Step 2: Step 3: Press the Mode button to place the heater in Standby Mode. Hold the Down Arrow and Mode buttons simultaneously for 3 secondsThe tech did the install and ran the heater only for a few minutes to check for ignition and stuff. He had done some other plumbing work so he didn't want to run in too long, or the pool pump either, so that the PVC glue really had some time to cure. The heater is a 400,000 BTU Hayward Universal HC Series Model HDF400 Pool Heater.Jul 21, 2013 47,820 Northern NJ Pool Size 35000 Surface Plaster Chlorine Salt Water Generator SWG Type Pentair Intellichlor IC-60 Examples: Gas heater and heat pump exchangers, temperature and pressure sensors, VSP drives, pump motors, blowers, fan motors, compressors, robotic cleaner motors and power supplys, circuit boards, flow-switches, UV lamps, and keypads. 1 year parts warranty only. No labor coverage. XE series Power Ends and single speed Super Pump® TEFC motors. Key Takeaways. The P5 code on Hayward pool heaters indicates a problem with the pressure switch. Common causes of the P5 code include clogged filters, improper water flow, and electrical issues. Troubleshooting steps for the P5 code involve checking water pressure, inspecting the heat exchanger, and verifying the gas supply.H-Series BTU (British Thermal Units – heating unit measure) Hayward Pool Heaters either Natural Gas or Propane, have BTU range from 150K BTU – up to 400K BTU. For more information and exact model specifications please visit the online store: Hayward Universal H Series 400K BTU Natural Gas Pool Heater -( H400FDN , Hayward ) Turn the thermostat all the way up on the heat pump. These units are not compatible with 3 wire remotes. For 2 wire air switch installations remove the jumper between terminals 1 & 2 and replace it with the 2 wires from your switch. Set the thermostat on the heat pump to the desired temp. Wiring Diagram HPABG / HP380. Reset the Heater: Sometimes, simply resetting the heater can clear the LO code. Turn off the heater, wait a few minutes, and then turn it back on. Professional Service: If you’ve tried the above steps and the LO code persists, it’s advisable to contact a professional pool heater technician. They can diagnose the issue more accurately and ...HU-429948972. 3 years ago. Hi I just hooked up a new 150,000 Hayward. With pump on low speed I get the LO code. So I put on high speed and LO code immediately goes away but then within 30 seconds I get HS code and shut down. 724-977-7371. Like.Hayward salt systems are a popular choice for homeowners looking to maintain their swimming pool water in a clean and safe condition. These systems use salt to generate chlorine, e...Nov 13, 2021 · My Hayward spa heater (installed 2018) is not heating the water and is displaying this LO code. I have read every troubleshooting guide and watched every video I could find. My diagnostics included: 1. Cleaned the filters, even ran the pump without the filters - still LO 2. Checked wires at pressure switch for continuity - still LO 3. Step 1. Turn off the power supply to the pool heater. Step 2. Wait for at least five minutes to allow the heater to cool down. Step 3. Turn the power back on and press the reset button. This button is typically located near the heater’s control panel or on the heater’s interior.You need to put the heater in STANDBY Mode to get the bO code on the heater display. Press the mode button once to get the heater in STANDBY Mode. First, press and hold on to the Down key. Then, press and hold down the MODE key as well. You need to keep holding both keys for about three seconds. At this point, the “bO” message …This blower vacuum switch is designed to use with Hayward Universal H-Series Low NOx pool heater models H150FDN, H150FDP, H200FDN, H200FDP, H250FDN, H250FDP, H300FDN, H300FDP, H350FDN, H350FDP, H400FDN, H400FDP. Weighs 4.8 pounds.Pool Length m: 10: Pool Width m: 6: Pool A. Depth m: 1.4: Pool surface area sq.m: 60: Pool surface area sq.ft: 645.6: Pool Volume cu.m: 84: Pool volume litrs: 84000: Pool Volume USGallons: 22176: Turnover time hr: 6: Flow rate required gpm : Flow rate required cu.m/h : Water Temperature Required deg C : Air temperature around pool deg C ...The Hayward Universal H-Series gas heater is one of the most energy-efficient Pool and Spa heating solutions on the market! Its ground-breaking hydraulic design reduces pump circulation run time, giving you an energy savings of up to 18%! This unit is perfect for the environmentally conscious Pool and Spa owner thanks to its Low NOx ...Step 1: Shut the power off and then take out all the screws from the display board. After taking off the whole board you’ll see that there is a lower panel on the other side. Take off the two screws and undo them. Step 2: You’ll see a ribbon cable. Take that off and then unscrew the underneath panel.A Answered on 1/17/2013 by InyoPools Product Specialist Patrick P.. For the Hayward Lo Nox heater, you would not need to purchase an additional vent if you are using it outside. If you are installing the heater outside, we recommend you purchasing a heater cover.Faulty water temperature switch, malfunctioning vent pressure switch, and defective temperature limit switch are accountable for displaying the Hayward pool heater LO code. Also, the damaged flow switch diaphragm and clogged filter are responsible for showing this code on your pool heater. However, going through the article, you will learn all about reasons behind LOThe Universal H-Series is an energy efficient, high performance, installation adaptable commitment to the pool service professional. Standard cupro nickel heat exchanger Excellent salt water and chemical corrosion resistance Exclusive "Totally Managed" cupro nickel heat exchanger water flow Same water velocity through all tubes for faster heatingFirst, reset your heater thermostat. Now, set the temperature point below 104 degrees. Then, set the function “Ok”. Always keep the temperature under 104 degrees to allow the heater to heat the water at this temperature. Note: Learn how to fix CE code on Hayward pool heater. 4.Adjust the water flow or call a professional if the pressure is too low. Clean the Filter: A dirty or clogged filter can cause Hayward Heater CE Code errors. Clean the filter thoroughly and replace it if necessary. This will improve the heater’s efficiency and prevent future issues. Inspect the Ignition System: If the above steps do not ...LO - PF - Sb - SF - ‘bo’ (bypass operation -2 wire ONLY) Press to place the heater in MODE MODE & STANDBY SPA POOL SERVICE HEAT TEMP SET MODE Max Pool Temp Limit is Pre-set To Energy-saving 90 F, See Owner’s Manual. ‘STANDBY’ Mode. for 3 seconds for ‘bo’ to appear. Heater must be in Spa or Pool Mode for bypass operation to …Aug 22, 2022 ... A super easy fix for a stuck button on a Hayward pool heater. Pool Heater Replacement Control Panel Keypad Membrane Switch Compatible with ...POOL AND SPA/HOT TUB HEATERS H150FD, H200FD, H250FD, H300FD, H350FD, H400FD & H500FD MODELS SERVICE & INSTALLATION MANUAL FOR YOUR SAFETY This product must be installed and serviced by authorized personnel, qualified in pool/ spa heater installation. Improper installation and/or operation can create carbon monoxide gasNOTE: The default Max temp lock-out set points are 90ºF (Pool) 104ºF (Spa). 14; Hayward H400FDN | Universal H Series Troubleshooting Guide - Page 15 ... Verify the pump is running & adequate water is flowing through heater. "LO" is NORMAL when the pump is turned off. Inspect water pressure switch Step 11A Continuity test Step 11B Inspect the ...Fits hayward universal h-series low nox pool heater models h150fdn, h150fdp, h200fdn, h200fdp, h250fdn, h250fdp ; Also fits hayward universal h-series low nox pool heater models h300fdn, h300fdp, h350fdn, h350fdp, h400fdn, h400fdp ; Weight 5.9 pounds ; Customer ratings by feature . Easy to install . 4.4 4.4 .Hayward Universal H-Series Pool Heater - 250,000 BTU Propane . $3,179.99. SKU. W3H250FDP. Icon Label Description Type Size Download; Hayward H-Series Universal Heater Brochure: Hayward H-Series Universal Heater: pdf: 1.3 MB: Download: Qty. Add to Cart. Add to Compare. 250,000 BTU Propane . Skip to the end of the images gallery.First, turn off the power to the pool heater circuit breaker. This should immediately shut down the pool heater. If the circuit breaker does not shut off, you should call a professional service technician to come out and inspect the problem. Next, check the fuse box located near the pool pump. The fuses should be in good condition.The Hayward Universal H-Series gas heater is one of the most energy-efficient Pool and Spa heating solutions on the market! Its ground-breaking hydraulic design reduces pump circulation run time, giving you an energy savings of up to 18%! This unit is perfect for the environmentally conscious Pool and Spa owner thanks to its Low NOx ...Hayward H400FDN Pdf User Manuals. View online or download Hayward H400FDN Owner's Manual, Troubleshooting Manual ... POOL AND SPA/HOT TUB HEATERS. Brand: Hayward | Category: Heater ... LO" Code. 46. Pressure Switch Adjustment. 49. IF" Code. 52. AC" Code. 57. AO" Code. 58. Heat Exchanger: Flow Requirements. 61.When it comes to taking care of your pool, one essential component that requires regular maintenance and occasional repairs is the pool pump. A well-functioning pool pump ensures p...TOP VENT PRO-INVERTER 13.5kW. SKU: PASRW030PUBP. Add to Compare. Showing 1-12 of 22. 1. 2. Heating swimming pools is a wise investment as it increases its value and extends the swimming season. So to graduate to a higher degree of comfort and control, choose a Hayward pool heater. Heater must then be in Spa or Pool Mode for operation. The heater will fire when instructed by the external control. Control Configuration- Two wire Note: 104° maximum temperature. Step 1: Step 2: Step 3: Press the Mode button to place the heater in Standby Mode. Hold the Down Arrow and Mode buttons simultaneously for 3 seconds By following these guidelines, you can quickly get your pool heater back up and running efficiently. Hayward Pool Heater Parts Diagram Hayward Pool Heater BO Code What Does BO Code Mean? The Hayward Pool Heater BO code indicates a flame-sensing fault. It means that the heater is unable to detect the flame properly.The Universal H-Series Heater is the world-class heater with an Earth-friendly conscience. While all Hayward H-Series heaters are energy-efficient, the Universal H-Series Low NOx heater has an 83-84 percent industry-leading thermal efficiency and complies with all current California and Texas air quality emission standards.What Does LO Code Mean On The Pool Heater? Hayward Pool Heater LO Code [Reasons + Solutions] 1. Water Temperature Switch Malfunction. 2. Defective Vent Pressure …Jun 7, 2020 ... Diagnosis of common problems on a Hayward pool heater.•Only qualified technicians should service heater •Replace damaged wiring immediately •Ensure appliance is properly ... "LO: Code 44-47 Change/Replace Combustion Chamber 20-26 12. "IF" Code 48-49 ... The default Max temp set points are 90ºF (Pool) 104ºF (Spa). When setting the max temp lock-out set point, the LEDs & display should ...Hayward salt systems are a popular choice for homeowners looking to maintain their swimming pool water in a clean and safe condition. These systems use salt to generate chlorine, e...Fits hayward universal h-series low nox pool heater models h150fdn, h150fdp, h200fdn, h200fdp, h250fdn, h250fdp; Also fits hayward universal h-series low nox pool heater models h300fdn, h300fdp, h350fdn, …Sep 6, 2012 ... The Hayward H400 (H Series) is no longer made and for good reason: consistent problems and a poor performance record. There are still some in ...Reach out via phone at (908) 355-7995 or email for unparalleled customer service and technical support to keep your pool in optimal condition. ... Hayward Insights provides expert advice, ... Pump, Filter, Heater, Lights, & Whole Goods Tech Support. 1 (908) 355-7995 (U.S.) Contact us by letter: Hayward Holdings, Inc.TOP VENT PRO-INVERTER 13.5kW. SKU: PASRW030PUBP. Add to Compare. Showing 1-12 of 22. 1. 2. Heating swimming pools is a wise investment as it increases its value and extends the swimming season. So to graduate to a higher degree of comfort and control, choose a Hayward pool heater.If your Hayward pool heater is displaying the LO code, it means that the limit string is open and the heater will shut down and enter lockout mode. To fix the problem and close …Examples: Gas heater and heat pump exchangers, temperature and pressure sensors, VSP drives, pump motors, blowers, fan motors, compressors, robotic cleaner motors and power supplys, circuit boards, flow-switches, UV lamps, and keypads. 1 year parts warranty only. No labor coverage. XE series Power Ends and single speed Super Pump® TEFC motors.Detailed Product Description. W3H250FDP previously H250FDP. For Altitudes Up To 3,048 Meters (10,000 Feet) Product Name: Hayward Universal H Series Low NOx 250,000 BTU Propane Swimming Pool Heater. Product Code: W3H250FDP. Maximum Altitude: 10,000 FT. The Hayward Universal H-Series gas heater is one of the most energy-efficient Pool and Spa heating solutions on the market! Its ground-breaking hydraulic design reduces pump circulation run time, giving you an energy savings of up to 18%! This unit is perfect for the environmentally conscious Pool and Spa owner thanks to its Low NOx capabilities. Model W3H150FDP. Cupro-Nickel heat exchanger with patented "V" baffle design increases the life of your unit and reduces heating time. Patented Polymer Header design provides superior hydraulic performance which saves energy and protects against damage due to high flow conditions. 2" x 2 1/2" CPVC unions. Electric – the energy where this heater comes from is through electricity. An electric heater is usually made of an electrical resistor, and it works throughout the principle of Joule Heating. Solar – Through the help of the sun’s heat and solar panels, the water heats, then the water from the pool has been pumped into the panels. It is heated before throwing it …Checking the Pool Heater Circuit Breaker. First, turn off the power to the pool heater circuit breaker. This should immediately shut down the pool heater. If the circuit breaker does not shut off, you should call a professional service technician to come out and inspect the problem. Next, check the fuse box located near the pool pump.NOTE: the maximum temperature set point is 104° F. 13. Hayward H250FDP | Universal H Series Troubleshooting Guide - Page 14. in bypass mode for external control. Step 1 Step 2 Press the 'MENU ICON' button to place the heater in 'STANDBY' mode. Step 3 Press and hold the minus & plus buttons for 3 seconds.The Hayward H-Series' Finn Plate cupro-nickel heat exchanger has special V-groove design for faster heating and longer life. Hayward Universal H-Series, Low NOx, 250,000 BTU, Propane Gas, Pool and Spa Heater delivers energy efficient heating to your pool's water that you can trust. Hayward Universal H-Series - Versatility & PowerFor hayward pool heater if code repair, check the pressure switch and ensure proper pressure is being reached. Hayward pool heaters display an “if” code when the pressure switch is not closed. This is caused by insufficient water flow, closed valves, air in the system, or a clogged filter. It is important to identify and fix the issue ...Dive in with a dealer near you. Our network of certified personnel can help you build your pool, recommend a product, repair a faulty product, and test your water. Find a professional near you. Hayward offers environmentally responsible, cutting-edge pool and spa equipment for residential and commercial, in-ground and above-ground pools.HeatPro Series Heat Pump. Hayward. SKU: HP21405T. Our new HeatPro Series of Heat Pumps utilize industry-first microchannel technology to get your pool water to the perfect temperature. Add to Compare. Add to Export. Overview. Specifications.303. 159K views 5 years ago. Are you experiencing a LO code on your Hayward H-Series pool heater? If so, give this video a watch for a few basic tips on how to work through the issue...The heater core in the Chevy Astro van acts like a small radiator that the engine coolant passes through. If the van's heater has trouble working, you may need to replace the core....First, check the power source. Make sure the heater is properly plugged in and that the circuit breaker or fuse hasn’t tripped. Next, check the water flow. A low water flow can cause the heater to overheat and shut down. Check the pool pump and filter for any clogs or debris that could be restricting water flow.INNOVATION MADE EASY. Hayward Commercial Aquatics offers a full range of industry-leading innovative products designed to work together as one total system to help every commercial pool perform at its absolute best. Our products set the technological standard while providing unmatched performance, efficiency, reliability, versatility and ease ...The Universal H-Series Low NOx heater has an 84 percent industry-leading thermal efficiency and complies with all current California air quality emission standards. The low NOx emission makes it a perfect choice for the environmentally concerned pool owner. Enjoy a warmer pool this season without your fuel costs skyrocketing.Dive in with a dealer near you. Our network of certified personnel can help you build your pool, recommend a product, repair a faulty product, and test your water. Find a professional near you. Hayward offers environmentally responsible, cutting-edge pool and spa equipment for residential and commercial, in-ground and above-ground pools.LO Code Pages 40-43 IF Code Pages 44-46 AC Code Page 47 AO Code Page 48-50 ... Heater must then be in Spa or Pool Mode for operation. The heater will ... Hayward … Its ground-breaking hydraulic design reduces pump circulation run time, giving you an energy savings of up to 18%! This unit is perfect for the environmentally conscious Pool and Spa owner thanks to its Low NOx capabilities. The Hayward Universal H-Series gas heater meets or exceeds the South Coast Air Quality Management District's (SCAQMD) Low ... Medallion Energy 3055 Tech Park Way Deland, FL 32724 407-786-0000. Hours Mon-Fri: 8am – 7pm Saturday: 9am – 5pm Sunday: By AppointmentIf your Hayward pool heater is displaying the LO code, it means that the limit string is open and the heater will shut down and enter lockout mode. To fix the problem and close the limit string , you’ll need to wait 2 minutes for the automatic restart.Locate a dealer near you for all your needs: building or servicing your pool, buying a product, or warranty support.

Hayward H400FDN Pdf User Manuals. View online or download Hayward H400FDN Owner's Manual, Troubleshooting Manual ... POOL AND SPA/HOT TUB HEATERS. Brand: Hayward | Category: Heater ... LO" Code. 46. Pressure Switch Adjustment. 49. IF" Code. 52. AC" Code. 57. AO" Code. 58. Heat Exchanger: Flow Requirements. 61.. Goat trophies in goat city bay

hayward pool heater lo

HeatPro Heat Pump 140k BTU. Hayward. SKU: HP21404TC. High performance, energy-efficient HeatPro heat pumps quietly and economically maintain the ideal water temperature at all times. Add to Compare. Add to Export. Overview. Specifications.Hayward Pool Heater IF Code What Does IF Code Mean? The Hayward Pool Heater IF code indicates an ignition failure. This means that the heater was unable to ignite the gas properly, preventing it from operating as intended. IF Code Quick Troubleshooting Steps. Refers to an ignition failure. Check gas supply and ensure … All HAYWARD Pool Heaters can be shipped to you at home. What are some of the most reviewed products in HAYWARD Pool Heaters? Some of the most reviewed products in HAYWARD Pool Heaters are the HAYWARD Universal H-Series Propane Gas 150,000 BTU Low NOx Pool Heater with 5 reviews, and the HAYWARD Universal H-Series Natural Gas 400,000 BTU Low NOx ... The Hayward Universal H-Series gas heater is one of the most energy-efficient Pool and Spa heating solutions on the market! Its ground-breaking hydraulic design reduces pump circulation run time, giving you an energy savings of up to 18%! This unit is perfect for the environmentally conscious Pool and Spa owner thanks to its Low NOx capabilities. Pomeade IDXL2DB1930 Display Board Replacement for Hayward Heater IDXL2DB1930 Display Board, Compatible with Hayward Universal H-Series Low Nox Induced Draft Heater, H400FDN HD150FDN dummy Hayward W3H150FDP Universal H-Series 150,000 BTU Propane Pool and Spa Heater for In-Ground Pools and SpasClean the hayward heater regularly to prevent any debris buildup, which can trigger the if code. Remove leaves, sticks, and other objects from the heater. Check the air filter and clean or replace it as needed. A dirty filter restricts airflow and can cause the heater to overheat, resulting in the if code.Below is the troubleshooting guide for Hayward pool heater error codes. Error codes show up on the digital screen of the H-Series H150, H200, H250, H300, H350, and H400 gas …H-Series BTU (British Thermal Units – heating unit measure) Hayward Pool Heaters either Natural Gas or Propane, have BTU range from 150K BTU – up to 400K BTU. For more information and exact model specifications please visit the online store: Hayward Universal H Series 400K BTU Natural Gas Pool Heater -( H400FDN , Hayward )NJ. Aug 7, 2021. #1. Hello, I have a H150FDN pool heater. It's worked all summer so far, but last week I noticed that it would turn on for a few minutes then turn off and show Lo. The filter is clean and the output is strong. I ordered a new pressure switch, but in the meantime I took the two wires that connect to the switch and made a jumper ...Adjust the water flow or call a professional if the pressure is too low. Clean the Filter: A dirty or clogged filter can cause Hayward Heater CE Code errors. Clean the filter thoroughly and replace it if necessary. This will improve the heater’s efficiency and prevent future issues. Inspect the Ignition System: If the above steps do not ...Hayward Insights provides expert advice, tips, and industry updates to help pool owners and enthusiasts with their swimming pool experience. Gain insight. ... Phase Heaters: 1.0000: Pool Type: In Ground: Product Dimensions: 24 " x 19 " x 29.5 "Product Height: 24 in: Product Length: 29.5 in: Product Weight: 135 lb: Product Width: 19 in:Show pool professionals that sell/service these specific products (restricts search to include only companies that sell/service each item checked):PitschPlumbing. Generally, LO refers to the pressure switch, water pressure. This can be caused by either the diaphram in the flow switch has failed or the filters is clogged and/or pump is unable to make enough pressure to make the switch. Open the front panel of the heater and look up in to the right. You will see a round part with 2 wires ... Its ground-breaking hydraulic design reduces pump circulation run time, giving you an energy savings of up to 18%! This unit is perfect for the environmentally conscious Pool and Spa owner thanks to its Low NOx capabilities. The Hayward Universal H-Series gas heater meets or exceeds the South Coast Air Quality Management District's (SCAQMD) Low ... Examples: Gas heater and heat pump exchangers, temperature and pressure sensors, VSP drives, pump motors, blowers, fan motors, compressors, robotic cleaner motors and power supplys, circuit boards, flow-switches, UV lamps, and keypads. 1 year parts warranty only. No labor coverage. XE series Power Ends and single speed Super Pump® TEFC motors.1. Locate the control panel. 2. Press the ‘Power’ button. 3. Set your desired temperature with the ‘Up’ and ‘Down’ buttons. 4. Press ‘Mode’ to activate the heating function. Pool Basics: How To Start/Light a Hayward H-Series Pool Heater.When your Hayward pool heater flashes the ‘bo code’, it’s signaling that there’s an issue with the bypass operation. Here’s a strategic approach to get your heater back to optimal functionality. Reset the Heater: Turn off the heater and the circuit breaker for 30 seconds. Power up the system again to see if the ‘bo code’ persists.Hayward H-Series heater for above ground pools and spas combines reliable technology with ease of operation and superior performance. H-Series heaters boast industry-leading hydraulic performance coupled with a 135,000 BTU rating for faster speed-to-heat capability. Their intuitive electronic panel is also quick and easy to operate, so pool ...The best pools start with hayward. #1 Products brand amongst pool professionals. 95+ Years in business, advancing pool equipment & technology. 2k Innovative team members committed to transforming the experience of water. About us Join our team.Oct 18, 2020 ... was getting CE code, aka Communication Error. Replaced main board, display board, and display panel..